A. TOTAL BEBAN PER HARI = WATT BEBAN ALAT DIKALI
JAM PEMAKAIAN
Misal ; 200
WATT x 12 JAM = 2400 W/HARI
B. MENGHITUNG JUMLAH MODUL
SOLAR CELL
~ KAPASITAS MODUL 50 WP
= 200W/HARI
~ KAPASITAS MODUL 100WP = 400W/HARI
RUMUS :
TOTAL BEBAN PER HARI DIBAGI KAPASITAS MODUL = JUMLAH MODUL
2400 W/HARI DIBAGI 400W/HARI
(MODUL 100WP) = 6 UNIT
*CADANGAN SYSTEM MODUL SOLAR
DITAMBAH MIN. 50% DARI JUMLAH MODUL (KALAU PIHAK KONSUMEN SETUJU) &
PENAMBAHAN HARUS GENAP HASILNYA :
6 UNIT + 50 % = 9 UNIT ------- DIGENAPKAN MENJADI = 10 BUAH
C. MENGHITUNG JUMLAH BATTERY
~ KAPASITAS BATTERY 60AH
(60AH x 12V) = 720W JAM
~ KAPASITAS BATTERY 100AH (100AH x 12V) = 1200W JAM
RUMUS :
TOTAL KAPASITAS MODUL DIBAGI KAPASITAS BATTERY = JUMLAH BATTERY
(6 UNIT x 400W/HARI) DIBAGI 1200W
JAM (AKI 100AH) = 2 UNIT
*CADANGAN SYSTEM BATTERY
DITAMBAH MIN. 50% DARI JUMLAH BATTERY (KALAU PIHAK KONSUMEN SETUJU) &
PENAMBAHAN HARUS GENAP HASILNYA :
2 UNIT + 50 % = 3 UNIT ------- DIGENAPKAN MENJADI = 4 BUAH
D. MENGHITUNG KAPASITAS & JUMLAH REGULATOR
~ KAPASITAS BCU 12V-10A (10AH
x 12V) ATAU SETARA = 120W DC
~ KAPASITAS BCU 24V-25A (25AH x 24V) ATAU SETARA = 600W DC
RUMUS :
*KALAU MODUL 400 WP DAN DIATASNYA HARUS MEMAKAI BCU 24V-25A
TOTAL KAPASITAS DAYA MODUL DIBAGI KAPASITAS BCU = JUMLAH BCU
(6 UNIT x 100WP) DIBAGI (600W
DC) BCU 24V-25 = 1 UNIT
E. MENENTUKAN KAPASITAS & JUMLAH INVERTER
KAPASITAS INVERTER DITENTUKAN
BESAR DAYA (WATT BEBAN ALAT) YANG DIBUTUHKAN DAN BESAR INVERTER HARUS LEBIH
BESAR MINIMAL 50% DARI DAYA (WATT BEBAN ALAT)
TERSEBUT.
MISAL ; DAYA (WATT BEBAN ALAT)
200 WATT , MAKA INVERTER 200 + 50% = 300 WATT. JADI BESAR INVERTER MINIMAL
300WATT.
INVERTER YANG DIPILIH SESUAI
STOK / TYPE YANG ADA DAN TEGANGAN INPUT INVERTER HARUS DISESUAIKAN PADA SYSTEM
TEGANGAN MODUL SOLAR CELL, BATTERY DAN BCU/REGULATOR, APA TEGANGAN 12V,
24V, 48 VDC.
MAKA INVERTER YANG DIPILIH PERHITUNGAN
DIATAS ADALAH 1000WATT TEGANGAN 24VDC DAN BISA MENGGUNAKAN TYPE GELOMBANG
MODIFIED ATAU PURE SINWAVE.
BEBAN (WATT BEBAN ALAT) DIATAS 700WATT HARUS MENGGUNAKAN INVERTER JENIS UPS
POWER BANK DENGAN GELOMBANG PURE SINWAVE
JUMLAH INVERTER TERGANTUNG
PERMINTAAN PELANGGAN.